DICOM to WebP Converter, Runs in Your Browser | MiConvert

DICOM to WebP Converter

Save a DICOM image as a compact 8-bit grayscale WebP, using the contrast stored in the file or the contrast you set on the sliders. Each file gives you one image: a multi-frame file exports only its first frame, and no DICOM header comes along.

🔒 Zero-Upload — Your files never leave your device
🏥

Drop your file here

DICOM (.dcm, single files or a whole series), NIfTI (.nii, .nii.gz), NRRD (.nrrd), MHA (.mha), MHD (.mhd + .raw)

Select File

Up to 1 GB per file • Processed locally

Zero Upload 100% Browser Processing No Sign Up 100% Free
DICOM → WEBP

Why turn a DICOM image into WebP

DICOM is the standard that scanners, PACS archives and radiology workstations use to store CT, MRI, X-ray and ultrasound images together with patient, study and acquisition details. A .dcm file usually holds 12- or 16-bit pixel values behind a long tag header. That is why a browser, a phone gallery or a content management system shows nothing when you try to open one. Normally you would need a DICOM viewer, such as the one in your PACS, RadiAnt or Horos.

This tool decodes the file inside your browser tab with the open-source daikon library, which also handles JPEG-lossless compressed pixel data. It maps the raw values to 8-bit grayscale using the Window Center and Window Width stored in the file. When those tags are missing, it uses an automatic window based on the 1st to 99th percentile of pixel values. The browser then encodes the picture as a WebP at quality 0.85. The file contents are never sent to MiConvert's servers.

The WebP keeps the full pixel grid at the image's native size, along with the contrast you see in the preview. Most of the rest is gone. The 16-bit values become 256 gray levels, WebP compression at this setting is lossy, and no tags, pixel spacing or orientation are written. A multi-frame file, such as an angiography run or a cine loop, exports only its first frame. Color (RGB) DICOM is not supported, because the renderer works in grayscale only.

WebP suits images headed for a web page, a teaching site, a slide deck or a messaging app, where it usually weighs less than a PNG of the same picture. If your destination rejects WebP, the same converter exports PNG, JPG or a one-page PDF. Treat the result as an illustration for teaching, documentation or sharing. It is a windowed 8-bit copy and is not suitable for diagnosis.

How to convert DICOM to WebP

  1. Export the image you want as a DICOM file (.dcm or .dicom) from your PACS, CD viewer or scanner. On a patient CD, pick an image file inside the DICOM folder, not the DICOMDIR index.
  2. If you have a whole series, choose the single file that holds the slice you need. The tool takes one file at a time, up to 200 MB.
  3. Drop the file on the page. The image is decoded on your machine, and a panel lists its modality, dimensions and bit depth.
  4. Check the preview. If the anatomy looks too dark or too flat, drag the window and level sliders. The export uses exactly the contrast on screen.
  5. Choose WebP, convert, and download the file. Before posting it anywhere, check the pixels for names, dates or IDs burned into the image, since nothing is removed from them.

What this DICOM to WebP converter does

  • Decodes standard DICOM Part-10 files with daikon, including JPEG-lossless compressed images
  • Uses the file's Window Center and Width tags, or an automatic 1st to 99th percentile window when they are absent
  • Window and level sliders for setting contrast before you export
  • WebP output at the image's native pixel dimensions, encoded at quality 0.85
  • Header summary (modality, size, bit depth) on screen, with no tags written into the WebP
  • PNG, JPG and single-page PDF output from the same tool when WebP is not accepted

Video Tutorial

An A-Z video guide on how to use MiConvert to change DICOM format to WEBP. This is the safest method to convert data without needing to download any applications to your device. 🔗 Format conversion

DICOM to WebP questions

Can you convert DICOM to JPEG or PDF instead of WebP?

Yes. The same converter saves the rendered image as a JPG at quality 0.92, as a lossless PNG, or as a PDF with the image centered on one A4 page. All of them share the limits described here: one 8-bit grayscale image per file, and no DICOM header in the output. JPEG is the safest choice for email and older software, while PNG avoids compression artifacts.

Can I turn a DICOM series into an MP4 or AVI video?

Not with this tool. It handles one file at a time, and a multi-frame file exports only its first frame, so it cannot build a movie. Desktop viewers such as Horos or OsiriX can export a series or cine loop as a movie, and many PACS workstations offer a similar export.

Can I convert DICOM to STL for 3D printing?

No. An STL model needs the whole stack of slices segmented into a surface, which is a different job from saving one picture. 3D Slicer is the common free route: load the series, segment the structure in the Segment Editor, then export the segmentation as STL.

Do I have to convert .dcm to .dicom first?

No. Both extensions are used for the same DICOM format, and the converter accepts either one directly. Renaming the file does not change its contents.

Can I convert JPG, PNG or NIfTI to DICOM here?

No. MiConvert only reads DICOM and turns it into ordinary images or a PDF. A valid DICOM needs patient, study and series tags that a JPG or PNG does not have. That kind of file is normally created through a PACS import function or a dedicated research tool, not a web converter.

Why is my WebP blank, or why does the page say the engine is not loaded?

A blank or black result usually means your browser is still running an older cached script. Hard-refresh the page (Ctrl+Shift+R, or Cmd+Shift+R on a Mac) and convert again. The message 'Medical converter engine not loaded' means the decoding libraries could not be fetched from cdn.jsdelivr.net, often because of an ad blocker or a hospital firewall. Allow that domain and reload. The tool cannot work offline.

What does 'Could not parse DICOM file' mean?

The decoder could not read the file. It may be damaged, cut short during copying, or encoded in a way the decoder does not support. Export the image again from the original system as a standard DICOM file. Also make sure you did not pick a DICOMDIR or a non-image object such as a structured report.

Is my scan uploaded, and is it stored anywhere?

The file's contents stay in your browser. It is decoded and converted there, and the WebP is created locally, so there is no server copy to keep or delete. Some information does leave your device: the decoding libraries load from cdn.jsdelivr.net, which sees your IP address. If Google Analytics is active, it receives the file name, size and detected format. A file over 200 MB is rejected, and its name, size and format are reported to our server. Rename files that contain a patient name before choosing them. The output carries no DICOM tags, but this tool is not an anonymizer: text burned into the pixels remains.